32665
32672
CT Wrist w/IVcon IMG14169
Machine Model: Canon AQ 16
Generated:
2021-04-20 20:18:16
IV Contrast 2 ml/sec using 22 g PIV Minimum See IV Guidelines
for other access lines.
IV Saline NA
Oral Contrast NA
Water NA
Contrast amount determined by weight and renal function.
Special Instructions: Prone, Affected arm above head.
Scanogram: AP/Lateral
Landmark: Area of Interest
A Venous
Scan Start Area of Interest
Scan Stop Area of Interest
Patient Position Prone
Scan Direction Craniocaudal
Scan Mode Helical
Scan Range If Volume NA
Scan Delay 90 seconds
Reconstruction 1 Thickness x Spacing 1 mm x 1 mm
Algorithm Body STD
FOV 24 cm
Reconstruction 2 Thickness x Spacing .5 mm x .3 mm
Algorithm Bone
FOV 24 cm
Reconstruction 3 Thickness x Spacing 2 mm x 1 mm
Algorithm Bone
FOV Coronal + Sagittal
FC 8
kVp 120 kVp
Scan FOV 24 cm
Pitch Standard
mA modulated mA
Rotation Time .5 sec
Detector Rows 0.5 mm x 16 mm
Indications: mass in the shoulder, upper extremity and supraclavicular regions, including arm scapula, shoulder, humerus, axilla, elbow, ulna, radius, forearm, wrist, and antecubital region .
No additional information.